Product Overview
Maximal77FV Access Power Controller distributes and switches power to access control systems and accessories. It converts a 220V AC (working range 198V AC - 256V AC), 50/60Hz input into sixteen (16) independently controlled 24V DC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
General Information
Name : Altronix MAXIMAL77FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 24VDC P/S at 9.7A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure , Altronix
Category : Access Power Controllers
UPC Code :
Specifications
General Information
ADI Part Number : AX-MAXIAL77
Brand Name : Altronix
Manufacturer : Altronix Corporation
Manufacturer Part Number : MAXIMAL77FV
Product Model : MAXIMAL77FV
Product Name : Access Power Controller With Power Supply/Chargers, 16 Fused Relay Outputs, Dual 24V DC P/S at 9.7A each, FAI, LinQ2 Ready, 220V AC, BC800 Enclosure
Product Type : Access Power Controller
Technical Information
Output Voltage : 24V DC
Physical Characteristics
Depth : 6.25"
Height : 26"
Weight (Approximate) : 33.9 lb
Width : 19"
Power Description
Input Voltage : 220V AC, 250V
Warranty
Limited Warranty : Lifetime
Miscellaneous
Environmental Certification : RoHS
Features : AC fail supervision (form "C" contacts), Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC)., Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure), Failover: Upon AC loss, instantaneous, Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs., Low battery and battery presence supervision (form "C" contact), Normally open (NO) or normally closed (NC) dry contact input., Notification trigger is selectable for 30 seconds (factory set) or 2 hours, Polarity reversal input from FACP signaling circuit., Type: Sealed lead acid or gel type